URA:
About gross floor area
1. What counts and doesnt count. All area is counted to center of parti wall.
2.Service ducts just like lift to be counted once.
2.Sky Terrace has main excluded area and also an additional one known as "residual area". This has to be <20%, with ST at >60% of floorplate and perimeter opening at 60% for it to be not counted.
BCA:
About accessibility:
1.Corridor width
2.Push Pull of door and wall setback
3.Lift if handicap friendly
4.Handicap toilets comply
FSSD:
About fire
1.Entry of fire engine, extent of access way
2.FCC
3.Fire fighting lift min 2 if >24m
4.Fire fighting lobby+ PWD
5.Staircase
6.Means of escape and occupant load
CBPU: Important to use the latest. current is 2013.
About refuse and toilet
1.Refuse top vent above roof min 2.1m
-Refuse amount based on typology will determine if bin center is needed ( >1000L/day)
-1 bin plus 1 extra needed
2.Toilet given by chart, based on GFA, for female and male
-Ambulant disabled ratio increased. (BCA accessibility 2013; 2 required for 6-10WC)
3.Tap point for cleaners sink
4.Diaper changing station
5.F&B: for a food shop with food stalls, min kitchen 8 sqm, min servery area 5sqm
-when >6 stalls, 1 handwashing basin with soap and towel, n litterbin
Showing posts with label CBPU. Show all posts
Showing posts with label CBPU. Show all posts
Tuesday, 11 July 2017
Subscribe to:
Posts (Atom)
Last days of June
Haven't cycled sinced March, when L left, and the bicycle was packed in the bag. to midyear, thats 3 months. probably the period that i...
-
Eventful day, started at 9am when S came around to pick us all in sequence. Public consultation was at Pasir Ris block 614 and then the oth...
-
TextAlign Tool Aligns it to specific pt or distance. either by aligning the selected one to the last one. or by clicking options, the ...
-
Today is about Ground Gardens and Sky Terraces and what encourages their proliferation in our city. In the same way that if there isn't...